PULS
YR40.241
Dual-input redundancy module (2 x inputs + 1 x output) with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - PULS (DIMENSION Y-series) - 12-28Vdc (12Vdc / 24Vdc nom.) / 40A output - with screw-clamp connections - DIN rail mounting (36mm width) - equivalent to #YR40241
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
YR40.241
Online Price
$210.00
Please add this item to cart to request a quote or contact us at [email protected]lectric.com for product availability.
YR40.241
Description
Dual-input redundancy module (2 x inputs + 1 x output) with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - PULS (DIMENSION Y-series) - 12-28Vdc (12Vdc / 24Vdc nom.) / 40A output - with screw-clamp connections - DIN rail mounting (36mm width) - equivalent to #YR40241
Specifications
Primary brand
PULS
Main function
Redundancy unit
Product series / family name
DIMENSION series
Sub-range name
Y-series
Functions
Dual-input redundancy module (2 x inputs + 1 x output)
Design
built-in decoupl. MOSFET (for 1+1 or N+1 redundancy)
ATEX approval
ATEX approval
Supply voltage (DC)
8.4Vdc-36.4Vdc (12Vdc / 24Vdc nom.)
Rated current
40A (at 28Vdc)
Output voltage (DC)
12-28Vdc (12Vdc / 24Vdc nom.)
Connection type
screw-clamp connections
Protection functions
short-circuit protection (65A threshold at 6V)
Series / parallel operation -- 1+1 Redundancy Use of 2 identical power supplies in parallel to provide continued operation following most failures in a single power supply. The 2 power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. N+1 Redundancy Use of 3 or more identical power supplies in parallel to provide continued operation following most failures in a single power supply. All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements.
Series / parallel operation -- 1+1 Redundancy Use of 2 identical power supplies in parallel to provide continued operation following most failures in a single power supply. The 2 power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. N+1 Redundancy Use of 3 or more identical power supplies in parallel to provide continued operation following most failures in a single power supply. All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements.
Net Width (mm)
36 mm
Mounting mode
DIN rail mounting
Dimensions
W36mm x H124mm x D127mm
Ambient air temperature for operation
-40...+70 °C
Current consumption
1000A peak max. inrush (at 8.4-36.4Vdc input)
Technical compatibility with
Suitable for all Power Supplies
Power dissipation/losses
(8.4-36.4Vdc input; 2x10A input) 2.15 W
(8.4-36.4Vdc input; 20A input) 2.65 W
(8.4-36.4Vdc input; 20A input) 2.65 W
Manufacturer product status
Commercialized
Equivalent to
YR40241
Capacitance
(output stage) 320 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
Benefits
For N+1 and 1+1 redundant systems
Dual input with single output
Suitable for all Power Supplies
Only 72mV voltage drop at 20A output current
Only 2.15W Loss at 20A and 6.3W at 40A Output Current
160% (65A) peak load capability
Reverse input polarity protection
Full power between -40°C and +70°C
Width only 36mm
Rugged metal housing
Easy wiring;
Distribution terminal for negative pole included
3 Year warranty
The YR40.241 is a redundancy module which can be used to build 1+1 and N+1 redundant system. It is equipped with 2 input channels which can be connected to power supplies with up to 20A output current and 1 output which can carry nominal currents up to 40A. The module is suitable for power supplies with constant current overload behaviour as well as any kind of Hiccup overload behaviour. In addition to the YR40.241 the YR40.242 is also available which is cost-optimized and suitable for all DIMENSION power supplies except the QT20 and QTD20 series. The novelty of this redundancy module is the utilization of mosfets instead of diodes for the decoupling of the 2 input channels. This reduces the heat generation and the voltage drop between input and output. The redundancy module does not require an additional auxiliary voltage and is self-sufficient even in case of a short circuit across the output. Due to the low power losses the unit is very slender and only requires 36mm width on the DIN-rail. Large connection terminals allow for a safe and fast installation with a large international approval package. This unit is suitable for nearly every application.
Dual input with single output
Suitable for all Power Supplies
Only 72mV voltage drop at 20A output current
Only 2.15W Loss at 20A and 6.3W at 40A Output Current
160% (65A) peak load capability
Reverse input polarity protection
Full power between -40°C and +70°C
Width only 36mm
Rugged metal housing
Easy wiring;
Distribution terminal for negative pole included
3 Year warranty
The YR40.241 is a redundancy module which can be used to build 1+1 and N+1 redundant system. It is equipped with 2 input channels which can be connected to power supplies with up to 20A output current and 1 output which can carry nominal currents up to 40A. The module is suitable for power supplies with constant current overload behaviour as well as any kind of Hiccup overload behaviour. In addition to the YR40.241 the YR40.242 is also available which is cost-optimized and suitable for all DIMENSION power supplies except the QT20 and QTD20 series. The novelty of this redundancy module is the utilization of mosfets instead of diodes for the decoupling of the 2 input channels. This reduces the heat generation and the voltage drop between input and output. The redundancy module does not require an additional auxiliary voltage and is self-sufficient even in case of a short circuit across the output. Due to the low power losses the unit is very slender and only requires 36mm width on the DIN-rail. Large connection terminals allow for a safe and fast installation with a large international approval package. This unit is suitable for nearly every application.
Electrical durability
(at 40°C; 20A output; 2x10A input) 553000 hours
(at 40°C; 20A output; 2x20A input) 355000 hours
(at 25°C; 40A output; 2x10A input) 1563000 hours
(at 25°C; 40A output; 2x20A input) 1003000 hours
(at 40°C; 20A output; 2x20A input) 355000 hours
(at 25°C; 40A output; 2x10A input) 1563000 hours
(at 25°C; 40A output; 2x20A input) 1003000 hours
Ripple
72mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
3386000h (at 40°C; 2x10A input; MTBF SN 29500 IEC 61709)
2706000h (at 40°C; 2x20A input; MTBF SN 29500 IEC 61709)
5667000h (at 25°C; 2x10A input; MTBF SN 29500 IEC 61709)
4686000h (at 25°C; 2x20A input; MTBF SN 29500 IEC 61709)
116000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GB40)
97000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GB40)
155000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GB25)
128000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GB25)
612000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GF40)
522000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GF40)
813000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GF25)
687000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GF25)
2706000h (at 40°C; 2x20A input; MTBF SN 29500 IEC 61709)
5667000h (at 25°C; 2x10A input; MTBF SN 29500 IEC 61709)
4686000h (at 25°C; 2x20A input; MTBF SN 29500 IEC 61709)
116000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GB40)
97000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GB40)
155000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GB25)
128000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GB25)
612000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GF40)
522000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GF40)
813000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GF25)
687000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GF25)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - YR40-241-1 - Datasheet.pdf | 01 Oct 2021 | English (US) |