PULS
QS40.361
AC/DC Power supply unit (PSU) / converter with ATEX approval - 50% power reserve - PULS (DIMENSION Q-series) - 22.9A (at 42Vdc) - 36Vdc-42Vdc (adjustable) / 26.7A output - with screw-clamp connections - Single-phase (1AC) input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)) - DIN rail mounting (125mm width) - equivalent to #QS40361
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
QS40.361
Online Price
$1,125.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
QS40.361
Description
AC/DC Power supply unit (PSU) / converter with ATEX approval - 50% power reserve - PULS (DIMENSION Q-series) - 22.9A (at 42Vdc) - 36Vdc-42Vdc (adjustable) / 26.7A output - with screw-clamp connections - Single-phase (1AC) input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)) - DIN rail mounting (125mm width) - equivalent to #QS40361
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
Q-series
Functions
AC/DC Power supply unit (PSU) / converter
50% power reserve
50% power reserve
Design
ATEX approval
50% power reserve
DC-OK rly. contact output
50% power reserve
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
164Vac turn-ON voltage
151Vac shutdown voltage
164Vac turn-ON voltage
151Vac shutdown voltage
Display
"DC-OK" LED
Type of network
Single-phase (1AC)
Rated current
26.7A (at 36Vdc)
22.9A (at 42Vdc)
22.9A (at 42Vdc)
Rated power
960W (at 36Vdc and 42Vdc)
1440W short-term (for 4s)
1440W short-term (for 4s)
Output voltage (DC)
36Vdc-42Vdc (adjustable)
100mV turn-ON overshoot
100mV turn-ON overshoot
Hold time
27ms (buffer time at 230Vac input)
27ms (buffer time at 120Vac input)
27ms (buffer time at 120Vac input)
Connection type
screw-clamp connections
Protection functions
output overvoltage protection (45.5Vdc typ. / 48Vdc max.)
active (input inrush current limiter)
Overload / short-circuit current -- min. 40A (max. 47A) load impedance <40mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 50V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
active (input inrush current limiter)
Overload / short-circuit current -- min. 40A (max. 47A) load impedance <40mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 50V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.946 (230Vac input)
0.935 (120Vac input)
0.931 (100Vac input)
0.935 (120Vac input)
0.931 (100Vac input)
Net Width (mm)
125 mm
Mounting mode
DIN rail mounting
Dimensions
W125mm x H124mm x D127mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
22A peak max. inrush (at 120Vac input)
16A peak max. inrush (at 230Vac input)
16A peak max. inrush (at 230Vac input)
Power dissipation/losses
(230Vac input; full output load) 54.8 W
(120Vac input; full output load) 66.7 W
(120Vac input; full output load) 66.7 W
Power factor (cos phi)
(230Vac input) 0.99
(120Vac input) 0.99
(120Vac input) 0.99
Manufacturer product status
Commercialized
Equivalent to
QS40361
Capacitance
(output stage) 4700 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
AC 100-240V Wide-range input
Width only 125mm Weight only 1.9kg
94.6% Full Load and Excellent Partial Load Efficiencies
50% BonusPower 1440W for up to 4s
70A High Peak Current for 10ms for Easy Fuse Tripping
Safe HiccupPLUS overload mode
Active PFC (Power Factor Correction)
Negligible low input inrush current surge
Full power between -25°C and +60°C
Current sharing feature for parallel use
Internal Data Logging for Troubleshooting Included.
Remote Control of Output Voltage
DC-OK relay contact
Shut-down Input
ATEX and IECEx Approved
3 Year warranty
The most outstanding features of this Dimension QS40.361 DIN-rail power supply are the extremely high efficiency and the small size which are achieved by a synchronous rectification a bridgeless PFC circuit and additional unique design details. Large power reserves of 150% and built-in large sized output capacitors support the starting of heavy loads such as DC motors or capacitive loads. In many cases this allows the use of a unit from a lower wattage class which saves space and money. High immunity to transients and power surges as well as low electromagnetic emissions makes usage in nearly every environment possible. The integrated input fuse as well as the near zero input inrush current make installation and usage simple. Diagnostics are easy due to the DC-OK relay a green DCOK LED and the red overload LED. A large international approval package for a variety of applications makes this unit suitable for nearly every application.
Width only 125mm Weight only 1.9kg
94.6% Full Load and Excellent Partial Load Efficiencies
50% BonusPower 1440W for up to 4s
70A High Peak Current for 10ms for Easy Fuse Tripping
Safe HiccupPLUS overload mode
Active PFC (Power Factor Correction)
Negligible low input inrush current surge
Full power between -25°C and +60°C
Current sharing feature for parallel use
Internal Data Logging for Troubleshooting Included.
Remote Control of Output Voltage
DC-OK relay contact
Shut-down Input
ATEX and IECEx Approved
3 Year warranty
The most outstanding features of this Dimension QS40.361 DIN-rail power supply are the extremely high efficiency and the small size which are achieved by a synchronous rectification a bridgeless PFC circuit and additional unique design details. Large power reserves of 150% and built-in large sized output capacitors support the starting of heavy loads such as DC motors or capacitive loads. In many cases this allows the use of a unit from a lower wattage class which saves space and money. High immunity to transients and power surges as well as low electromagnetic emissions makes usage in nearly every environment possible. The integrated input fuse as well as the near zero input inrush current make installation and usage simple. Diagnostics are easy due to the DC-OK relay a green DCOK LED and the red overload LED. A large international approval package for a variety of applications makes this unit suitable for nearly every application.
Electrical durability
(at 25°C; 13.3A output; 1AC 120Vac input) 303000 hours
(at 25°C; 13.3A output; 1AC 230Vac input) 334000 hours
(at 40°C; 13.3A output; 1AC 120Vac input) 107000 hours
(at 40°C; 13.3A output; 1AC 230Vac input) 118000 hours
(at 25°C; 26.7A output; 1AC 120Vac input) 156000 hours
(at 25°C; 26.7A output; 1AC 230Vac input) 165000 hours
(at 40°C; 26.7A output; 1AC 120Vac input) 55000 hours
(at 40°C; 26.7A output; 1AC 230Vac input) 58000 hours
(at 25°C; 13.3A output; 1AC 230Vac input) 334000 hours
(at 40°C; 13.3A output; 1AC 120Vac input) 107000 hours
(at 40°C; 13.3A output; 1AC 230Vac input) 118000 hours
(at 25°C; 26.7A output; 1AC 120Vac input) 156000 hours
(at 25°C; 26.7A output; 1AC 230Vac input) 165000 hours
(at 40°C; 26.7A output; 1AC 120Vac input) 55000 hours
(at 40°C; 26.7A output; 1AC 230Vac input) 58000 hours
Ripple
130mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
481000h (at 25°C; 120Vac input; MTBF SN 29500 IEC 61709)
537000h (at 25°C; 230Vac input; MTBF SN 29500 IEC 61709)
269000h (at 40°C; 120Vac input; MTBF SN 29500 IEC 61709)
300000h (at 40°C; 230Vac input; MTBF SN 29500 IEC 61709)
171000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F Ground Benign)
183000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F Ground Benign)
127000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F Ground Benign)
137000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F Ground Benign)
36000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F Ground Fixed)
39000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F Ground Fixed)
27000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F Ground Fixed)
30000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F Ground Fixed)
537000h (at 25°C; 230Vac input; MTBF SN 29500 IEC 61709)
269000h (at 40°C; 120Vac input; MTBF SN 29500 IEC 61709)
300000h (at 40°C; 230Vac input; MTBF SN 29500 IEC 61709)
171000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F Ground Benign)
183000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F Ground Benign)
127000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F Ground Benign)
137000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F Ground Benign)
36000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F Ground Fixed)
39000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F Ground Fixed)
27000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F Ground Fixed)
30000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F Ground Fixed)
Time delay
700-800ms start-up delay (400-480Vac input)
28ms rise time (nominal input; constant full current load; 0mF load capacitance)
35ms rise time (nominal input; constant full current load; 27mF load capacitance)
28ms rise time (nominal input; constant full current load; 0mF load capacitance)
35ms rise time (nominal input; constant full current load; 27mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - QS40-361-1 - Datasheet.pdf | 01 Oct 2021 | English (US) |