PULS
QS10.DNET
AC/DC Power supply unit (PSU) / converter with NEC Class 1 + DeviceNet approved - PULS (DIMENSION Q-series) - 24Vdc-24.5Vdc (adjustable) / 8A output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-188Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (60mm width) - equivalent to #QS10DNET
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
QS10.DNET
Online Price
$510.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
QS10.DNET
Description
AC/DC Power supply unit (PSU) / converter with NEC Class 1 + DeviceNet approved - PULS (DIMENSION Q-series) - 24Vdc-24.5Vdc (adjustable) / 8A output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-188Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (60mm width) - equivalent to #QS10DNET
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
Q-series
Functions
AC/DC Power supply unit (PSU) / converter
Design
NEC Class 1
DeviceNet approved
DC-OK rly. contact output
DeviceNet approved
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
81Vac turn-ON voltage
63Vac shutdown voltage (steady-state; no load)
55Vac shutdown voltage (dynamic value)
81Vac turn-ON voltage
63Vac shutdown voltage (steady-state; no load)
55Vac shutdown voltage (dynamic value)
Supply voltage (DC)
88Vdc-188Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)
Display
"DC-OK" LED
Type of network
Single-phase (1AC) or DC
Rated current
8A (at 24Vdc)
Rated power
192W
Output voltage (DC)
24Vdc-24.5Vdc (adjustable)
100mV turn-ON overshoot
100mV turn-ON overshoot
Hold time
34ms (buffer time at 230Vac input)
33ms (buffer time at 120Vac input)
33ms (buffer time at 120Vac input)
Connection type
spring-clamp connections
Protection functions
output overvoltage protection (27Vdc typ. / 29.5Vdc max.)
active (input inrush current limiter)
Overload / short-circuit current -- min. 7A (max. 10A) load impedance <100mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
active (input inrush current limiter)
Overload / short-circuit current -- min. 7A (max. 10A) load impedance <100mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.934 (230Vac input)
0.912 (120Vac input)
0.908 (100Vac input)
0.912 (120Vac input)
0.908 (100Vac input)
Net Width (mm)
60 mm
Mounting mode
DIN rail mounting
Dimensions
W60mm x H124mm x D117mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
10A peak max. inrush (at 120Vac input)
10A peak max. inrush (at 230Vac input)
10A peak max. inrush (at 230Vac input)
Power dissipation/losses
(230Vac input; full output load) 13.6 W
(120Vac input; full output load) 14.9 W
(120Vac input; full output load) 14.9 W
Power factor (cos phi)
(230Vac input) 0.92
(120Vac input) 0.98
(120Vac input) 0.98
Manufacturer product status
Commercialized
Equivalent to
QS10DNET
Capacitance
(output stage) 7000 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
AC 100-240V Wide-range input
DeviceNet Approved
NEC Class 1 Compliant
Width only 60mm
Efficiency up to 93.4%
Active power factor correction (PFC)
Negligible low Inrush Current Surge
Short-term Operation down to 60Vac and up to 300Vac
Full power between -25°C and +60°C
DC-OK relay contact
Quick-connect Spring-clamp Terminals
3 Year warranty
The QS10.DNET power supply is a derivate of the Dimension QS10 family which is specially designed to meet the DeviceNet requirement. The QS10.DNET exists beside the QS5.DNET which is the right choice to supply networks that use NEC Class 2 cables. The specialties of DeviceNet power supplies are; The nominal and overload currents are sized for the ratings of the DeviceNet cables. Large load capacitors can be charged in a very short period of time. After turn on the output voltage increases according to the DeviceNet timing specification. The upper level of the output level is limited to protect the network. The most outstanding features are a high efficiency compact size wide-range input voltage a very low inrush surge and a DC-ok contact. High immunity to transients and power surges and a low electromagnetic emission makes usage in nearly every environment possible. Unique quick-connect spring-clamp terminals allow a safe and fast installation. A large international approval package makes this unit suitable for nearly every situation.
DeviceNet Approved
NEC Class 1 Compliant
Width only 60mm
Efficiency up to 93.4%
Active power factor correction (PFC)
Negligible low Inrush Current Surge
Short-term Operation down to 60Vac and up to 300Vac
Full power between -25°C and +60°C
DC-OK relay contact
Quick-connect Spring-clamp Terminals
3 Year warranty
The QS10.DNET power supply is a derivate of the Dimension QS10 family which is specially designed to meet the DeviceNet requirement. The QS10.DNET exists beside the QS5.DNET which is the right choice to supply networks that use NEC Class 2 cables. The specialties of DeviceNet power supplies are; The nominal and overload currents are sized for the ratings of the DeviceNet cables. Large load capacitors can be charged in a very short period of time. After turn on the output voltage increases according to the DeviceNet timing specification. The upper level of the output level is limited to protect the network. The most outstanding features are a high efficiency compact size wide-range input voltage a very low inrush surge and a DC-ok contact. High immunity to transients and power surges and a low electromagnetic emission makes usage in nearly every environment possible. Unique quick-connect spring-clamp terminals allow a safe and fast installation. A large international approval package makes this unit suitable for nearly every situation.
Electrical durability
(at 40°C; 8A output; 1AC 120Vac input) 77000 hours
(at 40°C; 8A output; 1AC 230Vac input) 81000 hours
(at 40°C; 4A output; 1AC 120Vac input) 139000 hours
(at 40°C; 4A output; 1AC 230Vac input) 133000 hours
(at 25°C; 8A output; 1AC 120Vac input) 219000 hours
(at 25°C; 8A output; 1AC 230Vac input) 228000 hours
(at 40°C; 8A output; 1AC 230Vac input) 81000 hours
(at 40°C; 4A output; 1AC 120Vac input) 139000 hours
(at 40°C; 4A output; 1AC 230Vac input) 133000 hours
(at 25°C; 8A output; 1AC 120Vac input) 219000 hours
(at 25°C; 8A output; 1AC 230Vac input) 228000 hours
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
535000h (at 40°C; 120Vac input; MTBF SN 29500 IEC 61709)
581000h (at 40°C; 230Vac input; MTBF SN 29500 IEC 61709)
926000h (at 25°C; 120Vac input; MTBF SN 29500 IEC 61709)
1005000h (at 25°C; 230Vac input; MTBF SN 29500 IEC 61709)
341000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F)
345000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F)
469000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F)
474000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F)
581000h (at 40°C; 230Vac input; MTBF SN 29500 IEC 61709)
926000h (at 25°C; 120Vac input; MTBF SN 29500 IEC 61709)
1005000h (at 25°C; 230Vac input; MTBF SN 29500 IEC 61709)
341000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F)
345000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F)
469000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F)
474000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F)
Time delay
340-800ms start-up delay (100-230Vac input)
8ms rise time (nominal input; constant full current load; 0mF load capacitance)
15ms rise time (nominal input; constant full current load; 8mF load capacitance)
8ms rise time (nominal input; constant full current load; 0mF load capacitance)
15ms rise time (nominal input; constant full current load; 8mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - QS10-DN-T-1 - Datasheet.pdf | 01 Oct 2021 | English (US) |