PULS
PISA11.401
4-channel protection module (1input + 4 outputs) with NEC Class 2 - PULS (DIMENSION PISA11-series) - 4A (1A + 1A + 1A + 1A) - 24Vdc-28Vdc (adjustable) output - with screw-clamp connections - DIN rail mounting (45mm width) - equivalent to #PISA11401
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PISA11.401
Online Price
$130.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
PISA11.401
Description
4-channel protection module (1input + 4 outputs) with NEC Class 2 - PULS (DIMENSION PISA11-series) - 4A (1A + 1A + 1A + 1A) - 24Vdc-28Vdc (adjustable) output - with screw-clamp connections - DIN rail mounting (45mm width) - equivalent to #PISA11401
Specifications
Primary brand
PULS
Main function
Protection unit
Product series / family name
DIMENSION series
Sub-range name
PISA11-series
Functions
4-channel protection module (1input + 4 outputs)
Design
NEC Class 2
Supply voltage (DC)
18Vdc-30Vdc (24Vdc)
21.4Vdc (required input voltage for turning on the outputs)
21.4Vdc (required input voltage for turning on the outputs)
Rated current
4A (1A + 1A + 1A + 1A)
Output voltage (DC)
24Vdc-28Vdc (adjustable)
Connection type
screw-clamp connections
Protection functions
short-circuit protection (110ms shutdown time)
current limitation 9A - 12.7A adjustable threshold
current limitation 9A - 12.7A adjustable threshold
Net Width (mm)
45 mm
Mounting mode
DIN rail mounting
Dimensions
W45mm x H75mm x D91mm
Ambient air temperature for operation
-25...+70 °C
Processing time
(turn-on delay of output) 270 ms
Power dissipation/losses
(24V input; full output load) 1 W
Manufacturer product status
Commercialized
Equivalent to
PISA11401
Voltage drop
41mV / 0.041 V
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
NEC CLASS 2
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
NEC CLASS 2
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
Benefits
1 Input and 4 Current Controlled Outputs
Ensures Sufficient Supply Voltage for Critical Loads
even in the Event of an Fault
Protects Small Cable Sizes against Overload
Hassle-free Turn-on of Loads with Large Input
Capacitors
NEC Class 2 Compliant (1A and 2A Model)
Wide Temperature Range between -25°C and +70°C
On/Off Function of Outputs
Compact Design Width only 45mm
Remote Monitoring and Control Functions
3 Year warranty
This protection module fulfills 2 basic functions. First it distributes the current of a large power source to 4 lower current output channels and therefore allows for smaller wires to be used. The second function is to permit only so much current on the outputs that the input voltage of this unit (which corresponds to the output voltage of the power supply) does not fall below 21V. This ensures a safe and an uninterrupted supply voltage for sensitive equipments such as PLCs controls or sensors when they are connected directly to the same power supply as the PISA module. Less critical loads that are not affected to short voltage interruptions or that could even be the cause of a fault on the 24V power supply are connected to 1 of the 4 current controlled output channels of the PISA module.
Ensures Sufficient Supply Voltage for Critical Loads
even in the Event of an Fault
Protects Small Cable Sizes against Overload
Hassle-free Turn-on of Loads with Large Input
Capacitors
NEC Class 2 Compliant (1A and 2A Model)
Wide Temperature Range between -25°C and +70°C
On/Off Function of Outputs
Compact Design Width only 45mm
Remote Monitoring and Control Functions
3 Year warranty
This protection module fulfills 2 basic functions. First it distributes the current of a large power source to 4 lower current output channels and therefore allows for smaller wires to be used. The second function is to permit only so much current on the outputs that the input voltage of this unit (which corresponds to the output voltage of the power supply) does not fall below 21V. This ensures a safe and an uninterrupted supply voltage for sensitive equipments such as PLCs controls or sensors when they are connected directly to the same power supply as the PISA module. Less critical loads that are not affected to short voltage interruptions or that could even be the cause of a fault on the 24V power supply are connected to 1 of the 4 current controlled output channels of the PISA module.
Electrical durability
(at 40°C; 4x0.5A output) 243000 hours
(at 25°C; 4x0.5A output) 686000 hours
(at 25°C; 4x0.5A output) 686000 hours
MTBF (Mean Time Between Failures)
2347000h (at 40°C; 4x0.5A input; MTBF SN 29500 IEC 61709)
4039000h (at 25°C; 4x0.5A input; MTBF SN 29500 IEC 61709)
790000h (at 40°C; 4x0.5A input; MTBF MIL HDBK 217F)
1090000h (at 25°C; 4x0.5A input; MTBF MIL HDBK 217F)
4039000h (at 25°C; 4x0.5A input; MTBF SN 29500 IEC 61709)
790000h (at 40°C; 4x0.5A input; MTBF MIL HDBK 217F)
1090000h (at 25°C; 4x0.5A input; MTBF MIL HDBK 217F)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - PISA11-401 - Datasheet.pdf | 01 Oct 2021 | English (US) |