PULS
PIC240.241D
AC/DC Power supply unit (PSU) / converter - PULS (PIANO PIC-series) - 24Vdc-28Vdc (adjustable) / 10A / 240W output - with screw-clamp connections - Single-phase (1AC) input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)) - DIN rail mounting (49mm width) - equivalent to #PIC240241D
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PIC240.241D
Online Price
$225.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
PIC240.241D
Description
AC/DC Power supply unit (PSU) / converter - PULS (PIANO PIC-series) - 24Vdc-28Vdc (adjustable) / 10A / 240W output - with screw-clamp connections - Single-phase (1AC) input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)) - DIN rail mounting (49mm width) - equivalent to #PIC240241D
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
PIANO series
Sub-range name
PIC-series
Functions
AC/DC Power supply unit (PSU) / converter
Design
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
173Vac turn-ON voltage
107Vac shutdown voltage at 24V 0A
140Vac shutdown voltage at 24V 10A
173Vac turn-ON voltage
107Vac shutdown voltage at 24V 0A
140Vac shutdown voltage at 24V 10A
Display
"DC-OK" LED
Type of network
Single-phase (1AC)
Rated current
10A (at 24Vdc)
Rated power
150W (ambient less than 70°C)
240W (ambient less than 55°C)
240W (ambient less than 55°C)
Output voltage (DC)
24Vdc-28Vdc (adjustable)
200mV turn-ON overshoot
200mV turn-ON overshoot
Hold time
37ms (buffer time at 230Vac input)
37ms (buffer time at 120Vac input)
37ms (buffer time at 120Vac input)
Connection type
screw-clamp connections
Protection functions
output overvoltage protection (30.5Vdc typ. / 32Vdc max.)
active (input inrush current limiter)
Overload / short-circuit current -- 13A continuous current / 14.5A typ. intermitted current peak value for typ. 1s. Load impedance 50mΩ. Discharge current of output capacitors is not included. / Max. 5.5A intermitted current average value (R.M.S.) Load impedance 50mΩ
Series / parallel operation -- Power supplies can be paralleled for redundancy to gain higher system availability. Redundant systems require a certain amount of extra power to support the load in case 1 power supply unit fails. The simplest way is to put 2 power supplies in parallel. This is called a 1+1 redundancy. In case 1 power supply unit fails the other 1 is automatically able to support the load current without any interruption
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
active (input inrush current limiter)
Overload / short-circuit current -- 13A continuous current / 14.5A typ. intermitted current peak value for typ. 1s. Load impedance 50mΩ. Discharge current of output capacitors is not included. / Max. 5.5A intermitted current average value (R.M.S.) Load impedance 50mΩ
Series / parallel operation -- Power supplies can be paralleled for redundancy to gain higher system availability. Redundant systems require a certain amount of extra power to support the load in case 1 power supply unit fails. The simplest way is to put 2 power supplies in parallel. This is called a 1+1 redundancy. In case 1 power supply unit fails the other 1 is automatically able to support the load current without any interruption
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.952 (230Vac input)
0.94 (120Vac input)
0.932 (100Vac input)
0.94 (120Vac input)
0.932 (100Vac input)
Net Width (mm)
49 mm
Mounting mode
DIN rail mounting
Dimensions
W49mm x H124mm x D124mm
Material
Polycarbonate (PC) housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
32A peak max. inrush (at 230Vac input)
17A peak max. inrush (at 120Vac input)
17A peak max. inrush (at 120Vac input)
Power dissipation/losses
(230Vac input; full output load) 12.1 W
(120Vac input; full output load) 15.3 W
(120Vac input; full output load) 15.3 W
Power factor (cos phi)
(230Vac input) 0.95
(120Vac input) 0.99
(120Vac input) 0.99
Manufacturer product status
Commercialized
Equivalent to
PIC240241D
Capacitance
(output stage) 4400 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
AC 100-240V Wide-range input
Active PFC
Width only 49mm
Efficiency up to 95.2%
Safe HiccupPLUS overload mode
Full power between -25°C and +55°C
DC-OK relay contact
3 Year warranty
These PIANO series units are extraordinarily compact industrial grade power supplies that focus on the essential features needed in todays industrial applications. The excellent cost/performance ratio presents many new and exciting opportunities without compromising quality or reliability. The mechanically robust housing is made of a high-grade reinforced moulded material which permits the units to be used in surrounding temperatures up to 70°C. The unit is equipped with a wide-range input voltage stage many safety approvals and a wide operational temperature range which makes the unit applicable for global use. The addition of a DC-OK signal makes the unit suitable for many industry applications such as process control factory automation or many other critical applications where preventive function monitoring can help to avoid long downtimes.
Active PFC
Width only 49mm
Efficiency up to 95.2%
Safe HiccupPLUS overload mode
Full power between -25°C and +55°C
DC-OK relay contact
3 Year warranty
These PIANO series units are extraordinarily compact industrial grade power supplies that focus on the essential features needed in todays industrial applications. The excellent cost/performance ratio presents many new and exciting opportunities without compromising quality or reliability. The mechanically robust housing is made of a high-grade reinforced moulded material which permits the units to be used in surrounding temperatures up to 70°C. The unit is equipped with a wide-range input voltage stage many safety approvals and a wide operational temperature range which makes the unit applicable for global use. The addition of a DC-OK signal makes the unit suitable for many industry applications such as process control factory automation or many other critical applications where preventive function monitoring can help to avoid long downtimes.
Electrical durability
(at 40°C; 10A; 1AC 120Vac input) 55000 hours
(at 40°C; 10A; 1AC 230Vac input) 74000 hours
(at 40°C; 5A; 1AC 120Vac input) 93000 hours
(at 40°C; 5A; 1AC 230Vac input) 103000 hours
(at 25°C; 10A; 1AC 120Vac input) 156000 hours
(at 25°C; 10A; 1AC 230Vac input) 209000 hours
(at 25°C; 5A; 1AC 120Vac input) 262000 hours
(at 25°C; 5A; 1AC 230Vac input) 291000 hours
(at 40°C; 10A; 1AC 230Vac input) 74000 hours
(at 40°C; 5A; 1AC 120Vac input) 93000 hours
(at 40°C; 5A; 1AC 230Vac input) 103000 hours
(at 25°C; 10A; 1AC 120Vac input) 156000 hours
(at 25°C; 10A; 1AC 230Vac input) 209000 hours
(at 25°C; 5A; 1AC 120Vac input) 262000 hours
(at 25°C; 5A; 1AC 230Vac input) 291000 hours
Ripple
100mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
736000h (at +40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
822000h (at 40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
1267000h (at 25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
1391000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
345000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
374000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
471000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
508000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
78000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
85000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
101000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
111000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
822000h (at 40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
1267000h (at 25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
1391000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
345000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
374000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
471000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
508000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
78000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
85000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
101000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
111000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
Time delay
460ms start-up delay (100-230Vac input)
60ms rise time (nominal input; constant full current load; 0mF load capacitance)
230ms rise time (nominal input; constant full current load; 10mF load capacitance)
60ms rise time (nominal input; constant full current load; 0mF load capacitance)
230ms rise time (nominal input; constant full current load; 10mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - PIC240-241D-1 - Datasheet.pdf | 01 Oct 2021 | English (US) |