PULS
FPT500.245-018-103
Field AC/DC Power supply unit (PSU) / converter with 4 individually protected switchable outputs + IO-Link interface - PULS (FIEPOS eFused FPT500 eFused 3AC series) - 24Vdc-28Vdc (adjustable) / 20.8A / 500W output - 3-phase (3AC) input (323Vac-552Vac (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac nom.; 47-63Hz)) - IP65 / IP67 - Hanging and fixing via integrated keyholes or by screw mounting - with 4-pin M12 S-coded connector (INPUT; X1) + 5-pin M12 connector (IO-Link interface; X2) + 2 x 4-pin 7/8" connectors (OUTPUT; X3/X4) - equivalent to #FPT500245018103
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
FPT500.245-018-103
Online Price
$1,200.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
FPT500.245-018-103PULS - FIEPOS eFused series FPT500 - 3AC
Description
Field AC/DC Power supply unit (PSU) / converter with 4 individually protected switchable outputs + IO-Link interface - PULS (FIEPOS eFused FPT500 eFused 3AC series) - 24Vdc-28Vdc (adjustable) / 20.8A / 500W output - 3-phase (3AC) input (323Vac-552Vac (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac nom.; 47-63Hz)) - IP65 / IP67 - Hanging and fixing via integrated keyholes or by screw mounting - with 4-pin M12 S-coded connector (INPUT; X1) + 5-pin M12 connector (IO-Link interface; X2) + 2 x 4-pin 7/8" connectors (OUTPUT; X3/X4) - equivalent to #FPT500245018103
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
FIEPOS eFused series
Sub-range name
FPT500 eFused 3AC series
Functions
Field AC/DC Power supply unit (PSU) / converter
Design
4 individually protected switchable outputs
IO-Link interface
IO-Link interface
Supply voltage (AC)
323Vac-552Vac (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac nom.; 47-63Hz)
In case of loss of 1-phase device will continue to operate without interruption if loaded below limits (see documentation)
3 x 320Vac turn-ON voltage
3 x 300Vac shutdown voltage
In case of loss of 1-phase device will continue to operate without interruption if loaded below limits (see documentation)
3 x 320Vac turn-ON voltage
3 x 300Vac shutdown voltage
Display
LED bar-graph (20-200% load)
"Status" LED
3-color LEDs x 4 (OUT1-4 status)
"Status" LED
3-color LEDs x 4 (OUT1-4 status)
Type of network
3-phase (3AC)
Rated current
20.8A (at 24Vdc)
total max. output 25A (all 4 outputs; <45°C ambient)
total max. output 25A (all 4 outputs; <45°C ambient)
Rated power
600W (-25...+45°C)
500W (-25...+55°C)
350W at +70°C (derates linearly between +55°C and +70°C)
1000W short-term (for 5s; at -25...+55°C)
700W short-term (for 5s; at +55...+70°C)
500W (-25...+55°C)
350W at +70°C (derates linearly between +55°C and +70°C)
1000W short-term (for 5s; at -25...+55°C)
700W short-term (for 5s; at +55...+70°C)
Output voltage (DC)
24Vdc-28Vdc (adjustable)
500mV turn-ON overshoot
500mV turn-ON overshoot
Hold time
24ms (buffer time at 400/480Vac input)
Connection type
4-pin M12 S-coded connector (INPUT; X1)
5-pin M12 connector (IO-Link interface; X2)
2 x 4-pin 7/8" connectors (OUTPUT; X3/X4)
5-pin M12 connector (IO-Link interface; X2)
2 x 4-pin 7/8" connectors (OUTPUT; X3/X4)
Protection functions
output overvoltage protection (31.8Vdc typ. / 32.5Vdc max.)
Overload / short-circuit current -- individual inverse time curve for each output (eFused electronic protection; see datasheet for details)
Over-temperature protection -- Output shutdown with automatic restart. Temperature sensors are installed on critical components inside the unit and turn the unit OFF in safety critical situations which can happen e.g. when ambient temperature is too high ventilation is obstructed or the derating requirements are not followed. There is no correlation between the operating temperature and turn-OFF temperature since this is dependent on input voltage load and installation methods.
Series / parallel operation -- not possible
Back-feeding loads max. 35V / 4J -- The unit is resistant and does not show a malfunction when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. For all 4 outputs in total
Overload / short-circuit current -- individual inverse time curve for each output (eFused electronic protection; see datasheet for details)
Over-temperature protection -- Output shutdown with automatic restart. Temperature sensors are installed on critical components inside the unit and turn the unit OFF in safety critical situations which can happen e.g. when ambient temperature is too high ventilation is obstructed or the derating requirements are not followed. There is no correlation between the operating temperature and turn-OFF temperature since this is dependent on input voltage load and installation methods.
Series / parallel operation -- not possible
Back-feeding loads max. 35V / 4J -- The unit is resistant and does not show a malfunction when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. For all 4 outputs in total
Efficiency
0.958 (3x400Vac input)
0.956 (3x480Vac input)
0.956 (3x480Vac input)
Communication protocol
IO-Link
Mounting mode
Hanging and fixing via integrated keyholes or by screw mounting
Degree of protection
IP65
IP67
IP67
Dimensions
W182mm x H183mm x D59mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+55 °C
(with linear derating) +55...+70 °C
(with linear derating) +55...+70 °C
Current consumption
0.8A (3 x 400Vac input; full output; symmetrical phases)
0.66A (3 x 480Vac input; full output; symmetrical phases)
2.1A peak max. inrush (at 3x400Vac input)
2A peak max. inrush (at 3 x 480Vac input)
0.66A (3 x 480Vac input; full output; symmetrical phases)
2.1A peak max. inrush (at 3x400Vac input)
2A peak max. inrush (at 3 x 480Vac input)
Power dissipation/losses
(3x400Vac input; full output load) 20.8 W
(3x480Vac input; full output load) 23 W
(3x480Vac input; full output load) 23 W
Power factor (cos phi)
(3x400Vac input) 0.94
(3x480Vac input) 0.95
(3x480Vac input) 0.95
Manufacturer product status
Commercialized
Equivalent to
FPT500245018103
Capacitance
(output stage) 12500 μF
Compliant with standard(s)
CE marking
cULus
IECEE CB Scheme IEC 62368-1 / IEC 61010-2-201
IEC 61010
IEC 60950-1
SEMI F47
VDMA 24364
ROHS
REACH
WEEE
IEC/EN 61558-2-16
cULus
IECEE CB Scheme IEC 62368-1 / IEC 61010-2-201
IEC 61010
IEC 60950-1
SEMI F47
VDMA 24364
ROHS
REACH
WEEE
IEC/EN 61558-2-16
Benefits
IP65/67 protection
1000W peak 5s
3AC 380-480V Wide-range input
Up to 4 switchable outputs
95.6% full load and excellent partial load efficiencies
DIN rail mounting possible (option "D")
Output connected to PE (PELV)
Version without connection to PE on request
Large output capacitors
Not potted
Negligible low input inrush current surge
Full power between -25°C and +55°C
IO-Link
3 years warranty
The field power supplies of the FIEPOS eFused series have up to 4 current-limited outputs.
These devices make it easy to implement selective power distribution; protection and monitoring directly in the field.
The eFused series is therefore a space-saving; fused power supply system.
It is a real alternative to a power supply unit with an external; electronic protection module.
1000W peak 5s
3AC 380-480V Wide-range input
Up to 4 switchable outputs
95.6% full load and excellent partial load efficiencies
DIN rail mounting possible (option "D")
Output connected to PE (PELV)
Version without connection to PE on request
Large output capacitors
Not potted
Negligible low input inrush current surge
Full power between -25°C and +55°C
IO-Link
3 years warranty
The field power supplies of the FIEPOS eFused series have up to 4 current-limited outputs.
These devices make it easy to implement selective power distribution; protection and monitoring directly in the field.
The eFused series is therefore a space-saving; fused power supply system.
It is a real alternative to a power supply unit with an external; electronic protection module.
Electrical durability
(at 40°C; 500W output; 3AC 400Vac input) 43000 hours
(at 40°C; 250W output; 3AC 400Vac input) 177000 hours
(at 25°C; 500W output; 3AC 400Vac input) 135000 hours
(at 25°C; 250W output; 3AC 400Vac input) 466000 hours
(at 40°C; 500W output; 3AC 480Vac input) 37000 hours
(at 40°C; 250W output; 3AC 480Vac input) 168000 hours
(at 25°C; 500W output; 3AC 480Vac input) 119000 hours
(at 25°C; 250W output; 3AC 480Vac input) 476000 hours
(at 40°C; 250W output; 3AC 400Vac input) 177000 hours
(at 25°C; 500W output; 3AC 400Vac input) 135000 hours
(at 25°C; 250W output; 3AC 400Vac input) 466000 hours
(at 40°C; 500W output; 3AC 480Vac input) 37000 hours
(at 40°C; 250W output; 3AC 480Vac input) 168000 hours
(at 25°C; 500W output; 3AC 480Vac input) 119000 hours
(at 25°C; 250W output; 3AC 480Vac input) 476000 hours
Ripple
100mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
253000h (at +40°C; 300W output; 3AC 400Vac input; MTBF SN 29500 IEC 61709)
98000h (at 40°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
25000h (at 40°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
461000h (at +25°C; 300W output; 3AC 400Vac input; MTBF SN 29500 IEC 61709)
144000h (at 25°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
33000h (at 25°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
233000h (at +40°C; 300W output; 3AC 480Vac input; MTBF SN 29500 IEC 61709)
93000h (at 40°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
24000h (at 40°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
427000h (at +25°C; 300W output; 3AC 480Vac input; MTBF SN 29500 IEC 61709)
138000h (at 25°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
32000h (at 25°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
98000h (at 40°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
25000h (at 40°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
461000h (at +25°C; 300W output; 3AC 400Vac input; MTBF SN 29500 IEC 61709)
144000h (at 25°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
33000h (at 25°C; 300W output; 3AC 400Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
233000h (at +40°C; 300W output; 3AC 480Vac input; MTBF SN 29500 IEC 61709)
93000h (at 40°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
24000h (at 40°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
427000h (at +25°C; 300W output; 3AC 480Vac input; MTBF SN 29500 IEC 61709)
138000h (at 25°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
32000h (at 25°C; 300W output; 3AC 480Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
Time delay
2s start-up delay (400-480Vac input)
1ms rise time (nominal input; constant full current load; 0mF load capacitance)
1ms rise time (nominal input; constant full current load; 0mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - FIEPOS eFused series FPT500 - Datasheet.pdf | 01 Oct 2021 | English (US) |
PULS - FIEPOS eFused series FPT500.245-018-103 - FPT500.245-062-117 - FPT500.245-034-105 - Datasheet.pdf | 16 Oct 2022 | English (US) |
PULS - FIEPOS decentralized PSUs - Datasheet.pdf | 16 Oct 2022 | English (US) |