PULS
CT10.481
AC/DC Power supply unit (PSU) / converter - 20% power reserve - PULS (DIMENSION CT-series) - 3.75A (at 48Vdc; -25...+70°C) - 48Vdc-56Vdc (adjustable) / 6A / 240W output - with screw-clamp connections - 3-phase (3AC) input (323Vac-576Vac (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac nom.; 47-63Hz) (wide range; 3-phase input)) - DIN rail mounting (62mm width) - equivalent to #CT10481
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
CT10.481
Online Price
$450.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
CT10.481
Description
AC/DC Power supply unit (PSU) / converter - 20% power reserve - PULS (DIMENSION CT-series) - 3.75A (at 48Vdc; -25...+70°C) - 48Vdc-56Vdc (adjustable) / 6A / 240W output - with screw-clamp connections - 3-phase (3AC) input (323Vac-576Vac (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac nom.; 47-63Hz) (wide range; 3-phase input)) - DIN rail mounting (62mm width) - equivalent to #CT10481
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
CT-series
Functions
AC/DC Power supply unit (PSU) / converter
20% power reserve
20% power reserve
Design
20% power reserve
DC-OK rly. contact output
DC-OK rly. contact output
Supply voltage (AC)
323Vac-576Vac (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac nom.; 47-63Hz) (wide range; 3-phase input)
3 x 260Vac turn-ON voltage
3 x 185Vac shutdown voltage
3 x 260Vac turn-ON voltage
3 x 185Vac shutdown voltage
Display
"DC-OK" LED
Type of network
3-phase (3AC)
Rated current
6A (at 48Vdc; -25...+45°C)
3.75A (at 48Vdc; -25...+70°C)
5.2A (at 56Vdc; -25...+45°C)
3.2A (at 56Vdc; -25...+70°C)
6W/+60°C...+70°C (derating)
3.75A (at 48Vdc; -25...+70°C)
5.2A (at 56Vdc; -25...+45°C)
3.2A (at 56Vdc; -25...+70°C)
6W/+60°C...+70°C (derating)
Rated power
240W
Output voltage (DC)
48Vdc-56Vdc (adjustable)
300mV turn-ON overshoot
300mV turn-ON overshoot
Hold time
54ms (buffer time at 3x480Vac input)
34ms (buffer time at 3x400Vac input)
34ms (buffer time at 3x400Vac input)
Connection type
screw-clamp connections
Protection functions
output overvoltage protection (58.5Vdc typ. / 60Vdc max.)
active (input inrush current limiter)
Overload / short-circuit current -- max. 11.5A continuous current
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 63V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
active (input inrush current limiter)
Overload / short-circuit current -- max. 11.5A continuous current
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 63V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.929 (3x480Vac input)
0.928 (3x400Vac input)
0.928 (3x400Vac input)
Net Width (mm)
62 mm
Mounting mode
DIN rail mounting
Dimensions
W62mm x H124mm x D117mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
0.6A (3 x 480Vac input; full 48Vdc output)
0.7A (3 x 400Vac input; full 48Vdc output)
10A peak max. inrush (at 3x480Vac input)
10A peak max. inrush (at 3x400Vac input)
0.7A (3 x 400Vac input; full 48Vdc output)
10A peak max. inrush (at 3x480Vac input)
10A peak max. inrush (at 3x400Vac input)
Power dissipation/losses
(3x480Vac input; full output load) 18.3 W
(3x400Vac input; full output load) 18.6 W
(3x400Vac input; full output load) 18.6 W
Power factor (cos phi)
(3x480Vac input) 0.52
(3x400Vac input) 0.53
(3x400Vac input) 0.53
Manufacturer product status
Commercialized
Equivalent to
CT10481
Capacitance
(output stage) 2400 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
3AC 380-480V Wide-range input
2 or 3-Phase Operation Possible
Width only 62mm
Efficiency up to 92.9%
Excellent partial load efficiency
20% Output power reserve
Easy fuse tripping due to high overload current
Input -Transient Blanking Circuit Included
Minimal inrush current surge
3 Input Fuses Included
Current sharing feature for parallel use
Full power between -25°C and +60°C
3 Year warranty
The Dimension C-Series are cost optimized power supplies without compromising quality reliability and performance. The C-Series is part of the DIMENSION power supply family The most outstanding features of CT10.481 are the high efficiency electronic inrush current limitation active input transient filter and wide operational temperature range. The C-Series includes all the essential basic functions The devices have a power reserve of 20% included which may even be used continuously at temperatures up to +45°C. Additionally the CT10.481 can deliver 3 times the nominal output current for 10ms which helps to trip fuses on faulty output branches.
2 or 3-Phase Operation Possible
Width only 62mm
Efficiency up to 92.9%
Excellent partial load efficiency
20% Output power reserve
Easy fuse tripping due to high overload current
Input -Transient Blanking Circuit Included
Minimal inrush current surge
3 Input Fuses Included
Current sharing feature for parallel use
Full power between -25°C and +60°C
3 Year warranty
The Dimension C-Series are cost optimized power supplies without compromising quality reliability and performance. The C-Series is part of the DIMENSION power supply family The most outstanding features of CT10.481 are the high efficiency electronic inrush current limitation active input transient filter and wide operational temperature range. The C-Series includes all the essential basic functions The devices have a power reserve of 20% included which may even be used continuously at temperatures up to +45°C. Additionally the CT10.481 can deliver 3 times the nominal output current for 10ms which helps to trip fuses on faulty output branches.
Electrical durability
(at 40°C; 5A output; 3AC 400Vac input) 122000 hours
(at 40°C; 5A output; 3AC 480Vac input) 126000 hours
(at 40°C; 2.5A output; 3AC 400Vac input) 249000 hours
(at 40°C; 2.5A output; 3AC 480Vac input) 226000 hours
(at 40°C; 6A output; 3AC 400Vac input) 78000 hours
(at 40°C; 6A output; 3AC 480Vac input) 88000 hours
(at 25°C; 5A output; 3AC 400Vac input) 345000 hours
(at 25°C; 5A output; 3AC 480Vac input) 355000 hours
(at 25°C; 2.5A output; 3AC 400Vac input) 704000 hours
(at 25°C; 2.5A output; 3AC 480Vac input) 639000 hours
(at 25°C; 6A output; 3AC 400Vac input) 221000 hours
(at 25°C; 6A output; 3AC 480Vac input) 249000 hours
(at 40°C; 5A output; 2AC 400Vac input) 114000 hours
(at 40°C; 5A output; 2AC 480Vac input) 120000 hours
(at 40°C; 2.5A output; 2AC 400Vac input) 253000 hours
(at 40°C; 2.5A output; 2AC 480Vac input) 234000 hours
(at 40°C; 6A output; 2AC 400Vac input) 76000 hours
(at 40°C; 6A output; 2AC 480Vac input) 81000 hours
(at 25°C; 5A output; 2AC 400Vac input) 322000 hours
(at 25°C; 5A output; 2AC 480Vac input) 341000 hours
(at 25°C; 2.5A output; 2AC 400Vac input) 716000 hours
(at 25°C; 2.5A output; 2AC 480Vac input) 662000 hours
(at 25°C; 6A output; 2AC 400Vac input) 215000 hours
(at 25°C; 6A output; 2AC 480Vac input) 229000 hours
(at 40°C; 5A output; 3AC 480Vac input) 126000 hours
(at 40°C; 2.5A output; 3AC 400Vac input) 249000 hours
(at 40°C; 2.5A output; 3AC 480Vac input) 226000 hours
(at 40°C; 6A output; 3AC 400Vac input) 78000 hours
(at 40°C; 6A output; 3AC 480Vac input) 88000 hours
(at 25°C; 5A output; 3AC 400Vac input) 345000 hours
(at 25°C; 5A output; 3AC 480Vac input) 355000 hours
(at 25°C; 2.5A output; 3AC 400Vac input) 704000 hours
(at 25°C; 2.5A output; 3AC 480Vac input) 639000 hours
(at 25°C; 6A output; 3AC 400Vac input) 221000 hours
(at 25°C; 6A output; 3AC 480Vac input) 249000 hours
(at 40°C; 5A output; 2AC 400Vac input) 114000 hours
(at 40°C; 5A output; 2AC 480Vac input) 120000 hours
(at 40°C; 2.5A output; 2AC 400Vac input) 253000 hours
(at 40°C; 2.5A output; 2AC 480Vac input) 234000 hours
(at 40°C; 6A output; 2AC 400Vac input) 76000 hours
(at 40°C; 6A output; 2AC 480Vac input) 81000 hours
(at 25°C; 5A output; 2AC 400Vac input) 322000 hours
(at 25°C; 5A output; 2AC 480Vac input) 341000 hours
(at 25°C; 2.5A output; 2AC 400Vac input) 716000 hours
(at 25°C; 2.5A output; 2AC 480Vac input) 662000 hours
(at 25°C; 6A output; 2AC 400Vac input) 215000 hours
(at 25°C; 6A output; 2AC 480Vac input) 229000 hours
Ripple
100mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
1050000h (at 40°C; 3x400Vac input; MTBF SN 29500 IEC 61709)
1047000h (at 40°C; 3x480Vac input; MTBF SN 29500 IEC 61709)
1804000h (at 25°C; 3x400Vac input; MTBF SN 29500 IEC 61709)
1799000h (at 25°C; 3x480Vac input; MTBF SN 29500 IEC 61709)
1018000h (at 40°C; 2x400Vac input; MTBF SN 29500 IEC 61709)
1023000h (at 40°C; 2x480Vac input; MTBF SN 29500 IEC 61709)
1765000h (at 25°C; 2x400Vac input; MTBF SN 29500 IEC 61709)
1770000h (at 25°C; 2x480Vac input; MTBF SN 29500 IEC 61709)
438000h (at 40°C; 3x400Vac input; MTBF MIL HDBK 217F)
424000h (at 40°C; 3x480Vac input; MTBF MIL HDBK 217F)
585000h (at 25°C; 3x400Vac input; MTBF MIL HDBK 217F)
568000h (at 25°C; 3x480Vac input; MTBF MIL HDBK 217F)
101000h (at 40°C; 3x400Vac input; MTBF MIL HDBK 217F)
99000h (at 40°C; 3x480Vac input; MTBF MIL HDBK 217F)
134000h (at 25°C; 3x400Vac input; MTBF MIL HDBK 217F)
132000h (at 25°C; 3x480Vac input; MTBF MIL HDBK 217F)
437000h (at 40°C; 2x400Vac input; MTBF MIL HDBK 217F)
424000h (at 40°C; 2x480Vac input; MTBF MIL HDBK 217F)
583000h (at 25°C; 2x400Vac input; MTBF MIL HDBK 217F)
569000h (at 25°C; 2x480Vac input; MTBF MIL HDBK 217F)
101000h (at 40°C; 2x400Vac input; MTBF MIL HDBK 217F)
99000h (at 40°C; 2x480Vac input; MTBF MIL HDBK 217F)
134000h (at 25°C; 2x400Vac input; MTBF MIL HDBK 217F)
132000h (at 25°C; 2x480Vac input; MTBF MIL HDBK 217F)
1047000h (at 40°C; 3x480Vac input; MTBF SN 29500 IEC 61709)
1804000h (at 25°C; 3x400Vac input; MTBF SN 29500 IEC 61709)
1799000h (at 25°C; 3x480Vac input; MTBF SN 29500 IEC 61709)
1018000h (at 40°C; 2x400Vac input; MTBF SN 29500 IEC 61709)
1023000h (at 40°C; 2x480Vac input; MTBF SN 29500 IEC 61709)
1765000h (at 25°C; 2x400Vac input; MTBF SN 29500 IEC 61709)
1770000h (at 25°C; 2x480Vac input; MTBF SN 29500 IEC 61709)
438000h (at 40°C; 3x400Vac input; MTBF MIL HDBK 217F)
424000h (at 40°C; 3x480Vac input; MTBF MIL HDBK 217F)
585000h (at 25°C; 3x400Vac input; MTBF MIL HDBK 217F)
568000h (at 25°C; 3x480Vac input; MTBF MIL HDBK 217F)
101000h (at 40°C; 3x400Vac input; MTBF MIL HDBK 217F)
99000h (at 40°C; 3x480Vac input; MTBF MIL HDBK 217F)
134000h (at 25°C; 3x400Vac input; MTBF MIL HDBK 217F)
132000h (at 25°C; 3x480Vac input; MTBF MIL HDBK 217F)
437000h (at 40°C; 2x400Vac input; MTBF MIL HDBK 217F)
424000h (at 40°C; 2x480Vac input; MTBF MIL HDBK 217F)
583000h (at 25°C; 2x400Vac input; MTBF MIL HDBK 217F)
569000h (at 25°C; 2x480Vac input; MTBF MIL HDBK 217F)
101000h (at 40°C; 2x400Vac input; MTBF MIL HDBK 217F)
99000h (at 40°C; 2x480Vac input; MTBF MIL HDBK 217F)
134000h (at 25°C; 2x400Vac input; MTBF MIL HDBK 217F)
132000h (at 25°C; 2x480Vac input; MTBF MIL HDBK 217F)
Time delay
90ms start-up delay (3x400-3x480Vac input)
55ms rise time (nominal input; constant full current load; 0mF load capacitance)
140ms rise time (nominal input; constant full current load; 5mF load capacitance)
55ms rise time (nominal input; constant full current load; 0mF load capacitance)
140ms rise time (nominal input; constant full current load; 5mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - CT10-481 - Datasheet.pdf | 01 Oct 2021 | English (US) |