PULS
CP20.241-R1
AC/DC Power supply unit (PSU) / converter with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - 20% power reserve - PULS (DIMENSION CP-series) - 24Vdc (fixed voltage) / 24A / 480W output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - IP20 - DIN rail mounting (48mm width) - equivalent to #CP20241R1
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
CP20.241-R1
Online Price
$570.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
CP20.241-R1
Description
AC/DC Power supply unit (PSU) / converter with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - 20% power reserve - PULS (DIMENSION CP-series) - 24Vdc (fixed voltage) / 24A / 480W output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - IP20 - DIN rail mounting (48mm width) - equivalent to #CP20241R1
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
CP-series
Functions
AC/DC Power supply unit (PSU) / converter
20% power reserve
20% power reserve
Design
built-in decoupl. MOSFET (for 1+1 or N+1 redundancy)
ATEX approval
20% power reserve
DC-OK rly. contact output
ATEX approval
20% power reserve
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
264-300Vac input overvoltage (for 500ms max.)
82Vac turn-ON voltage
72Vac shutdown voltage (steady-state)
55Vac shutdown voltage (250ms max.)
264-300Vac input overvoltage (for 500ms max.)
82Vac turn-ON voltage
72Vac shutdown voltage (steady-state)
55Vac shutdown voltage (250ms max.)
Supply voltage (DC)
88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)
Display
"DC-OK" LED
Type of network
Single-phase (1AC) or DC
Rated current
24A (at 48Vdc; -25...+45°C)
20A (at 48Vdc; +45...+60°C)
15A (at 48Vdc; +70°C)
20A (at 48Vdc; +45...+60°C)
15A (at 48Vdc; +70°C)
Rated power
576W (-25...+45°C)
480W (-25...+60°C)
360W at +70°C (derates linearly between +60°C and +70°C)
480W (-25...+60°C)
360W at +70°C (derates linearly between +60°C and +70°C)
Output voltage (DC)
24Vdc (fixed voltage)
1000mV turn-ON overshoot
1000mV turn-ON overshoot
Hold time
32ms (buffer time at 120/230Vac input)
Connection type
spring-clamp connections
Protection functions
output overvoltage protection (30.5Vdc typ. / 32Vdc max.)
Overload / short-circuit current -- 9.8A max. (R.M.S.) current / (typ. 29A) intermitted current peak for typ. 2s at load impedance 10mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Power supplies can be paralleled to increase the output power. For redundancy applications 1 extra power supply is always needed for sufficient output current in case 1 unit fails.
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Overload / short-circuit current -- 9.8A max. (R.M.S.) current / (typ. 29A) intermitted current peak for typ. 2s at load impedance 10mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Power supplies can be paralleled to increase the output power. For redundancy applications 1 extra power supply is always needed for sufficient output current in case 1 unit fails.
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.952 (230Vac input)
0.938 (120Vac input)
0.938 (120Vac input)
Net Width (mm)
48 mm
Mounting mode
DIN rail mounting
Degree of protection
IP20
Dimensions
W48mm x H124mm x D127mm
Material
Aluminium housing
Ambient air temperature for operation
-40...+70 °C
Current consumption
2.25A (230Vac input; full output)
4.28A (120Vac input; full output)
5.17A (100Vac input; full output)
4.64A (110Vdc input; 24Vdc / 10A output)
5.5A peak max. inrush (at 230Vac input)
12A peak max. inrush (at 120Vac input)
4.28A (120Vac input; full output)
5.17A (100Vac input; full output)
4.64A (110Vdc input; 24Vdc / 10A output)
5.5A peak max. inrush (at 230Vac input)
12A peak max. inrush (at 120Vac input)
Power dissipation/losses
(230Vac input; full output load) 24.2 W
(120Vac input; full output load) 31.7 W
(120Vac input; full output load) 31.7 W
Power factor (cos phi)
(230Vac input) 0.98
(120Vac input) 0.99
(120Vac input) 0.99
Manufacturer product status
Commercialized
Equivalent to
CP20241R1
Capacitance
(output stage) 8000 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
AC 100-240V Wide-range input
Width only 48mm
Built-in decoupling MOSFET for 1+1 and n+1 redundancy
Efficiency up to 95.2%
20% Output power reserve
Safe HiccupPLUS overload mode
Easy fuse breaking - 3 times nominal current for 12ms
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -40°C and +60°C
DC-OK relay contact
Current sharing feature included
3 Year warranty
The Dimension CP-Series are cost optimized power supplies without compromising quality / reliability / performance.
The most outstanding features of the CP10.241-R1/-R2/-R3 units are the high efficiency; electronic inrush current limitation; active PFC; wide operational temperature range and the extraordinary small size.
The units include a decoupling MOSFET for building 1+1 or N+1 redundant power supply systems.
These redundancy power supplies come with 3 connection terminal options; screw terminals; spring clamp terminals or plug connector terminals which allows replacement on an active application.
Width only 48mm
Built-in decoupling MOSFET for 1+1 and n+1 redundancy
Efficiency up to 95.2%
20% Output power reserve
Safe HiccupPLUS overload mode
Easy fuse breaking - 3 times nominal current for 12ms
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -40°C and +60°C
DC-OK relay contact
Current sharing feature included
3 Year warranty
The Dimension CP-Series are cost optimized power supplies without compromising quality / reliability / performance.
The most outstanding features of the CP10.241-R1/-R2/-R3 units are the high efficiency; electronic inrush current limitation; active PFC; wide operational temperature range and the extraordinary small size.
The units include a decoupling MOSFET for building 1+1 or N+1 redundant power supply systems.
These redundancy power supplies come with 3 connection terminal options; screw terminals; spring clamp terminals or plug connector terminals which allows replacement on an active application.
Electrical durability
(at 40°C; 10A output; 1AC 120Vac input) 136000 hours
(at 25°C; 10A output; 1AC 120Vac input) 386000 hours
(at 40°C; 20A output; 1AC 120Vac input) 53000 hours
(at 25°C; 20A output; 1AC 120Vac input) 150000 hours
(at 40°C; 24A output; 1AC 120Vac input) 25000 hours
(at 25°C; 24A output; 1AC 120Vac input) 69000 hours
(at 40°C; 10A output; 1AC 230Vac input) 164000 hours
(at 25°C; 10A output; 1AC 230Vac input) 465000 hours
(at 40°C; 20A output; 1AC 230Vac input) 90000 hours
(at 25°C; 20A output; 1AC 230Vac input) 253000 hours
(at 40°C; 24A output; 1AC 230Vac input) 47000 hours
(at 25°C; 24A output; 1AC 230Vac input) 134000 hours
(at 25°C; 10A output; 1AC 120Vac input) 386000 hours
(at 40°C; 20A output; 1AC 120Vac input) 53000 hours
(at 25°C; 20A output; 1AC 120Vac input) 150000 hours
(at 40°C; 24A output; 1AC 120Vac input) 25000 hours
(at 25°C; 24A output; 1AC 120Vac input) 69000 hours
(at 40°C; 10A output; 1AC 230Vac input) 164000 hours
(at 25°C; 10A output; 1AC 230Vac input) 465000 hours
(at 40°C; 20A output; 1AC 230Vac input) 90000 hours
(at 25°C; 20A output; 1AC 230Vac input) 253000 hours
(at 40°C; 24A output; 1AC 230Vac input) 47000 hours
(at 25°C; 24A output; 1AC 230Vac input) 134000 hours
Ripple
100mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
412000h (at +40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
169000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
36000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
768000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
231000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
47000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
543000h (at +40°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
199000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
42000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
976000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
272000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
56000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
169000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
36000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
768000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
231000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
47000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
543000h (at +40°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
199000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
42000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
976000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
272000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
56000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
Time delay
450ms start-up delay (100-230Vac input)
145ms rise time (nominal input; full constant current load; 0mF load capacitance)
160ms rise time (nominal input; full constant current load; 20mF load capacitance)
145ms rise time (nominal input; full constant current load; 0mF load capacitance)
160ms rise time (nominal input; full constant current load; 20mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - CP20.24x - Datasheet.pdf | 01 Oct 2021 | English (US) |