PULS
CP20.241
AC/DC Power supply unit (PSU) / converter with ATEX approval - 20% power reserve - PULS (DIMENSION CP-series) - 24Vdc-28Vdc (adjustable) / 20A / 480W output - with screw-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (48mm width) - equivalent to #CP20241
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
CP20.241
Online Price
$585.00
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
CP20.241
Description
AC/DC Power supply unit (PSU) / converter with ATEX approval - 20% power reserve - PULS (DIMENSION CP-series) - 24Vdc-28Vdc (adjustable) / 20A / 480W output - with screw-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)) - DIN rail mounting (48mm width) - equivalent to #CP20241
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
CP-series
Functions
AC/DC Power supply unit (PSU) / converter
20% power reserve
20% power reserve
Design
ATEX approval
20% power reserve
DC-OK rly. contact output
20% power reserve
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
82Vac turn-ON voltage
72Vac shutdown voltage
82Vac turn-ON voltage
72Vac shutdown voltage
Supply voltage (DC)
88Vdc-180Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc nom.)
Display
"DC-OK" LED
Type of network
Single-phase (1AC) or DC
Rated current
20A (at 24Vdc)
Rated power
480W
Output voltage (DC)
24Vdc-28Vdc (adjustable)
500mV turn-ON overshoot
500mV turn-ON overshoot
Hold time
32ms (buffer time at 120/230Vac input)
Connection type
screw-clamp connections
Protection functions
output overvoltage protection (30.5Vdc typ. / 32Vdc max.)
Overload / short-circuit current -- 9.8A max. (R.M.S.) current / (typ. 29A) intermitted current peak for typ. 1s at load impedance 10mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Devices can be paralleled to increase the output power. The output voltage shall be adjusted to the same value (+/-100mV) with the same load conditions on all devices (or the devices can be left with the factory settings). Devices can be paralleled for 1+1 redundancy to gain higher system availability using a redundancy module
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Overload / short-circuit current -- 9.8A max. (R.M.S.) current / (typ. 29A) intermitted current peak for typ. 1s at load impedance 10mΩ
Series / parallel operation -- devices of the same type can be connected in series for higher output voltages / Devices can be paralleled to increase the output power. The output voltage shall be adjusted to the same value (+/-100mV) with the same load conditions on all devices (or the devices can be left with the factory settings). Devices can be paralleled for 1+1 redundancy to gain higher system availability using a redundancy module
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.956 (230Vac input)
0.942 (120Vac input)
0.936 (100Vac input)
0.942 (120Vac input)
0.936 (100Vac input)
Net Width (mm)
48 mm
Mounting mode
DIN rail mounting
Dimensions
W48mm x H124mm x D127mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
5.5A peak max. inrush (at 230Vac input)
12A peak max. inrush (at 120Vac input)
12A peak max. inrush (at 120Vac input)
Power dissipation/losses
(230Vac input; full output load) 22.1 W
(120Vac input; full output load) 29.6 W
(120Vac input; full output load) 29.6 W
Power factor (cos phi)
(230Vac input) 0.98
(120Vac input) 0.996
(120Vac input) 0.996
Manufacturer product status
Commercialized
Equivalent to
CP20241
Capacitance
(output stage) 8500 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
AC 100-240V Wide-range input
Width only 48mm
Efficiency up to 95.6%
Excellent partial load efficiency
20% Output power reserve
Easy fuse breaking - 3 times nominal current for 12ms
Safe HiccupPLUS overload mode
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
DC-OK relay contact
Current sharing feature for parallel use
3 Year warranty
The Dimension CP-Series are cost optimized power supplies without compromising quality / reliability / performance.
The most outstanding features of the CP20 series are the high efficiency; electronic inrush current limitation; active PFC; wide operational temperature range and the extraordinary small size.
The CP20.242 features an enhanced DC input voltage range.
The devices have a power reserve of 20% included; which may even be used continuously up to +45°C.
High immunity to transients and power surges as well as low electromagnetic emission; a DC-OK relay contact and a large international approval package make this unit suitable for nearly every situation.
Width only 48mm
Efficiency up to 95.6%
Excellent partial load efficiency
20% Output power reserve
Easy fuse breaking - 3 times nominal current for 12ms
Safe HiccupPLUS overload mode
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
DC-OK relay contact
Current sharing feature for parallel use
3 Year warranty
The Dimension CP-Series are cost optimized power supplies without compromising quality / reliability / performance.
The most outstanding features of the CP20 series are the high efficiency; electronic inrush current limitation; active PFC; wide operational temperature range and the extraordinary small size.
The CP20.242 features an enhanced DC input voltage range.
The devices have a power reserve of 20% included; which may even be used continuously up to +45°C.
High immunity to transients and power surges as well as low electromagnetic emission; a DC-OK relay contact and a large international approval package make this unit suitable for nearly every situation.
Electrical durability
(at 40°C; 10A output; 1AC 120Vac input) 149000 hours
(at 40°C; 10A output; 1AC 230Vac input) 173000 hours
(at 25°C; 10A output; 1AC 120Vac input) 422000 hours
(at 25°C; 10A output; 1AC 230Vac input) 488000 hours
(at 40°C; 20A output; 1AC 120Vac input) 60000 hours
(at 40°C; 20A output; 1AC 230Vac input) 94000 hours
(at 25°C; 20A output; 1AC 120Vac input) 169000 hours
(at 25°C; 20A output; 1AC 230Vac input) 265000 hours
(at 40°C; 24A output; 1AC 120Vac input) 31000 hours
(at 40°C; 24A output; 1AC 230Vac input) 54000 hours
(at 25°C; 24A output; 1AC 120Vac input) 88000 hours
(at 25°C; 24A output; 1AC 230Vac input) 152000 hours
(at 40°C; 10A output; 1AC 230Vac input) 173000 hours
(at 25°C; 10A output; 1AC 120Vac input) 422000 hours
(at 25°C; 10A output; 1AC 230Vac input) 488000 hours
(at 40°C; 20A output; 1AC 120Vac input) 60000 hours
(at 40°C; 20A output; 1AC 230Vac input) 94000 hours
(at 25°C; 20A output; 1AC 120Vac input) 169000 hours
(at 25°C; 20A output; 1AC 230Vac input) 265000 hours
(at 40°C; 24A output; 1AC 120Vac input) 31000 hours
(at 40°C; 24A output; 1AC 230Vac input) 54000 hours
(at 25°C; 24A output; 1AC 120Vac input) 88000 hours
(at 25°C; 24A output; 1AC 230Vac input) 152000 hours
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
445000h (at +40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
191000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
42000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
832000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
263000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
55000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
590000h (at +40°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
226000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
50000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1060000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
313000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
67000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
191000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
42000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
832000h (at +25°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
263000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
55000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
590000h (at +40°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
226000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
50000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1060000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
313000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
67000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
Time delay
450ms start-up delay (100-230Vac input)
145ms rise time (nominal input; constant full current load; 0mF load capacitance)
160ms rise time (nominal input; constant full current load; 20mF load capacitance)
145ms rise time (nominal input; constant full current load; 0mF load capacitance)
160ms rise time (nominal input; constant full current load; 20mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - CP20.241 - Datasheet.pdf | 01 Oct 2021 | English (US) |