PULS
CP10.241-M1
AC/DC Power supply unit (PSU) / converter - medical applications - PULS (DIMENSION CP-series) - 24Vdc-28Vdc (adjustable) / 10A / 240W output - with spring-clamp connections - Single-phase (1AC) input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)) - DIN rail mounting (39mm width) - equivalent to #CP10241M1
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
CP10.241-M1
Online Price
$320.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
CP10.241-M1
Description
AC/DC Power supply unit (PSU) / converter - medical applications - PULS (DIMENSION CP-series) - 24Vdc-28Vdc (adjustable) / 10A / 240W output - with spring-clamp connections - Single-phase (1AC) input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)) - DIN rail mounting (39mm width) - equivalent to #CP10241M1
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
CP-series
Functions
AC/DC Power supply unit (PSU) / converter
20% power reserve
20% power reserve
Design
medical applications
DC-OK rly. contact output
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
264-300Vac input overvoltage (for 500ms max.)
80Vac turn-ON voltage
70Vac shutdown voltage (steady-state; no load)
55Vac shutdown voltage (dynamic value)
264-300Vac input overvoltage (for 500ms max.)
80Vac turn-ON voltage
70Vac shutdown voltage (steady-state; no load)
55Vac shutdown voltage (dynamic value)
Display
"DC-OK" LED
Type of network
Single-phase (1AC)
Rated current
10A (at 24Vdc)
6W/+60°C...+70°C (derating)
6W/+60°C...+70°C (derating)
Rated power
240W
Output voltage (DC)
24Vdc-28Vdc (adjustable)
200mV turn-ON overshoot
200mV turn-ON overshoot
Hold time
37ms
Connection type
spring-clamp connections
Protection functions
output overvoltage protection (30.5Vdc typ. / 32Vdc max.)
Overload / short-circuit current -- 5A average (R.M.S.) current / min. 28A (typ. 30.5A) up to 12ms at load impedance <45mΩ
Series / parallel operation -- not possible
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Overload / short-circuit current -- 5A average (R.M.S.) current / min. 28A (typ. 30.5A) up to 12ms at load impedance <45mΩ
Series / parallel operation -- not possible
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.952 (230Vac input)
0.936 (120Vac input)
0.929 (100Vac input)
0.936 (120Vac input)
0.929 (100Vac input)
Net Width (mm)
39 mm
Mounting mode
DIN rail mounting
Dimensions
W39mm x H124mm x D117mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
11A peak max. inrush (at 230Vac input)
7A peak max. inrush (at 120Vac input)
7A peak max. inrush (at 120Vac input)
Power dissipation/losses
(230Vac input; full output load) 12.1 W
(120Vac input; full output load) 16.4 W
(120Vac input; full output load) 16.4 W
Power factor (cos phi)
(230Vac input) 0.97
(120Vac input) 0.99
(120Vac input) 0.99
Application type
Medical applications
Manufacturer product status
Commercialized
Equivalent to
CP10241M1
Capacitance
(output stage) 4400 μF
Compliant with standard(s)
CE marking
EAC Registration
IEC 60601-1; 3rd edition; Medical
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
EAC Registration
IEC 60601-1; 3rd edition; Medical
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
2MOPP Safety Approved for Medical applications
According to IEC 60601-1 3rd edition
EMC Tested for Medical Use According to IEC 60601-1-2
4th edition
Quick-connect Spring-clamp Terminals
AC 100-240V Wide-range input
Width only 39mm
Efficiency up to 95.2% Excellent partial load efficiency
20% Output power reserve
Safe HiccupPLUS overload mode
Easy fuse breaking due to high overload peak current
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
DC-OK relay contact
3 Years Limited Warranty
The CP10.241-M1 is a DIN-rail mountable single-phase input power supply for industrial use and for use in medical equipment. It provides a stabilized and galvanically separated SELV/PELV output voltage. The specialty of this power supply is the 2MOPP (2 means of patient protection) safety approval for medical use and the fulfillment of the required EMC tests for professional healthcare facility and home healthcare environments. The CP-Series is part of the DIMENSION power supply family. The most outstanding features of CP10.241-M1 are the high efficiency advanced inrush current limitation active PFC and the wide operational temperature range. High immunity to transients and power surges as well as low electromagnetic emission; a DC-OK relay contact and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.
According to IEC 60601-1 3rd edition
EMC Tested for Medical Use According to IEC 60601-1-2
4th edition
Quick-connect Spring-clamp Terminals
AC 100-240V Wide-range input
Width only 39mm
Efficiency up to 95.2% Excellent partial load efficiency
20% Output power reserve
Safe HiccupPLUS overload mode
Easy fuse breaking due to high overload peak current
Active power factor correction (PFC)
Minimal inrush current surge
Full power between -25°C and +60°C
DC-OK relay contact
3 Years Limited Warranty
The CP10.241-M1 is a DIN-rail mountable single-phase input power supply for industrial use and for use in medical equipment. It provides a stabilized and galvanically separated SELV/PELV output voltage. The specialty of this power supply is the 2MOPP (2 means of patient protection) safety approval for medical use and the fulfillment of the required EMC tests for professional healthcare facility and home healthcare environments. The CP-Series is part of the DIMENSION power supply family. The most outstanding features of CP10.241-M1 are the high efficiency advanced inrush current limitation active PFC and the wide operational temperature range. High immunity to transients and power surges as well as low electromagnetic emission; a DC-OK relay contact and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.
Electrical durability
(at 40°C; 5A output; 1AC 120Vac input) 141000 hours
(at 40°C; 5A output; 1AC 230Vac input) 176000 hours
(at 40°C; 10A output; 1AC 120Vac input) 75000 hours
(at 40°C; 10A output; 1AC 230Vac input) 120000 hours
(at 40°C; 12A output; 1AC 120Vac input) 59000 hours
(at 40°C; 12A output; 1AC 230Vac input) 101000 hours
(at 25°C; 5A output; 1AC 120Vac input) 399000 hours
(at 25°C; 5A output; 1AC 230Vac input) 499000 hours
(at 25°C; 10A output; 1AC 230Vac input) 211000 hours
(at 25°C; 10A output; 1AC 120Vac input) 338000 hours
(at 25°C; 12A output; 1AC 230Vac input) 166000 hours
(at 25°C; 12A output; 1AC 120Vac input) 286000 hours
(at 40°C; 5A output; 1AC 230Vac input) 176000 hours
(at 40°C; 10A output; 1AC 120Vac input) 75000 hours
(at 40°C; 10A output; 1AC 230Vac input) 120000 hours
(at 40°C; 12A output; 1AC 120Vac input) 59000 hours
(at 40°C; 12A output; 1AC 230Vac input) 101000 hours
(at 25°C; 5A output; 1AC 120Vac input) 399000 hours
(at 25°C; 5A output; 1AC 230Vac input) 499000 hours
(at 25°C; 10A output; 1AC 230Vac input) 211000 hours
(at 25°C; 10A output; 1AC 120Vac input) 338000 hours
(at 25°C; 12A output; 1AC 230Vac input) 166000 hours
(at 25°C; 12A output; 1AC 120Vac input) 286000 hours
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
560000h (at +40°C; full output; 1AC 120Vac input; MTBF SN 29500 IEC 61709)
661000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
1017000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1176000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
188000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
213000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
252000h (at +25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
290000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
40000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
47000h (at +40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
51000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
61000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
661000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
1017000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
1176000h (at +25°C; full output; 1AC 230Vac input; MTBF SN 29500 IEC 61709)
188000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
213000h (at 40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
252000h (at +25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
290000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
40000h (at 40°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Fixed GF40)
47000h (at +40°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Benign GB40)
51000h (at 25°C; full output; 1AC 120Vac input; MTBF MIL HDBK 217F Ground Benign GB25)
61000h (at 25°C; full output; 1AC 230Vac input; MTBF MIL HDBK 217F Ground Fixed GF25)
Time delay
240-300ms start-up delay (100-230Vac input)
30ms rise time (nominal input; constant full current load; 0mF load capacitance)
75ms rise time (nominal input; constant full current load; 10mF load capacitance)
30ms rise time (nominal input; constant full current load; 0mF load capacitance)
75ms rise time (nominal input; constant full current load; 10mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - CP10-241-M1 - Datasheet.pdf | 01 Oct 2021 | English (US) |